Pure water equipment routine maintenance methods

Article Source:InternetPopularity:110Issuing Time:2018-01-16
Pure water equipment every day in non-stop work, in order to be able to ensure the normal operation of various devices, and to maintain the best water treatment effect, we should regularly carry out routine maintenance and repair of equipment, in addition to the electrical part of the electrical and related personnel responsible, The rest can be operated by the operator himself. Pure water equipment, routine maintenance can start from several aspects:
1, check and adjust the necessary parts, mobilize the movement of the entire moving parts, and often check or replace the wearing parts. Timely management of pure water equipment, timely detection of changes in operating parameters.
2, check the necessary fasteners and production control devices, to be safe and reliable. Regular inspection Replacement of precision filter cartridge, replacement time 2 to 3 months to replace, often check the precision filter for the presence of gas.
3, cleaning, inspection. Adjust the electrical related parts, check the electrical contact is good, the connection is solid and reliable. High-pressure pump inlet pressure is about 0.5MPa above, and in time to pure water equipment manufactured by the water inspection.
4, promptly clean, wipe the inner and outer surface of the dead parts of the device to remove dirt on the surface of the filter device for pure water equipment for regular backwash.
5, if necessary, the demolition of equipment, to carry out adjustment and repair work. On the long-term use of equipment or formaldehyde protection methods to prevent bacterial growth.
6, routine maintenance should reach the appearance of clean, showing true colors, smooth oil. Lubricate well. Net oil bright. The equipment operates flexibly and is in normal operation. Regularly carry out low-pressure cleaning on the reverse osmosis membrane of the deactivated purified water equipment, and try to clean it at least once a day, especially in the summer. If disabled for more than seven days of equipment should be 0.5 to 1 sodium sulfite or 0.5 to 1 formaldehyde solution for maintenance of reverse osmosis membrane. And timely detection of protective solution PH value.